Residual aneurysm after metal coils treatment detected by spectral CT
Abstract
Digital subtraction angiography (DSA) is currently the gold standard for diagnosing the residue or recurrence of aneurysm after treatment, especially in the presence of metal coils. However, DSA is an invasive procedure which may cause additional trauma and economic burden to patients. Spectral CT imaging, as a newly introduced CT imaging mode, produces monochromatic image sets that is able to reduce beam-hardening and other metal-related artifacts, and has found its use in several clinical applications including brain imaging to reduce beam-hardening artifacts. In this study, we describe a case of spectral CT imaging in follow-up of the metal coils treatment and detection of a small leaf of residual aneurysm after metal coils treatment.
Key words
Residual aneurysm; DSA; spectral CT
A 48-year-old woman presented to our hospital with a headache lasting for 22 days. A conventional head CT imaging indicated a subarachnoid hemorrhage. One week later, digital subtraction angiography (DSA) revealed a lobulated aneurysm existing in the anterior communicating artery (Figure 1). The diameter of the neck of the aneurysm was about 2.98 mm, and the size of aneurysm was about 4.33 mm × 2.54 mm (Figure 1). The patient refused a surgical clipping of the aneurysms, therefore embolization was performed. Because the neck of the lobulated aneurysm was relatively broad and the coil could not be stabilized, a small leaf of the aneurysm was left. Six months later, a spectral CT angiography was performed. The monochromatic images at 100 keV photon energy obtained with spectral CT indicated that the metal coils in the bigger aneurysm were still intact and in place with no metal artifacts in the vicinity of the metal coils. The residual small aneurysm could also be clearly displayed (Figure 2). The follow-up DSA reaffirmed the existence of the small residual aneurysm (Figure 3). The size and pattern of the residual aneurysm were consistent between the DSA and spectral CT images.
Conventional CT scans have not been routinely used in reviewing the aneurysm which is filled with the metal coils because the hyperdense metal artifacts could interfere with the observer’s views. On the other hand, spectral CT, with its ability to generate a set of monochromatic images ranging from 40 to 140 keV and incorporate advanced metal artifact reduction sequence (MARS), can eliminate beam-hardening artifacts and minimize metal artifacts. Spectral CT effectively eliminated the radial metal artifacts by the metal coils in the aneurysm and clearly show the fine structure around the metal. As the spectral CT is introduced to clinical application, this new scanning method might become a new alternative to DSA in evaluating aneurysm after metal coils treatment.
Acknowledgements
Disclosure: The authors declare no conflict of interest.