Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging

  
@article{QIMS12854,
	author = {Xiaoliang Zhang and Alastair Martin and Caroline Jordan and Prasheel Lillaney and Aaron Losey and Yong Pang and Jeffrey Hu and Mark Wilson and Daniel Cooke and Steven W. Hetts},
	title = {Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging},
	journal = {Quantitative Imaging in Medicine and Surgery},
	volume = {7},
	number = {2},
	year = {2016},
	keywords = {},
	abstract = {Background: It is technically challenging to design compact yet sensitive miniature catheter radio frequency (RF) coils for endovascular interventional MR imaging. 
Methods: In this work, a new design method for catheter RF coils is proposed based on the coaxial transmission line resonator (TLR) technique. Due to its distributed circuit, the TLR catheter coil does not need any lumped capacitors to support its resonance, which simplifies the practical design and construction and provides a straightforward technique for designing miniature catheter-mounted imaging coils that are appropriate for interventional neurovascular procedures. The outer conductor of the TLR serves as an RF shield, which prevents electromagnetic energy loss, and improves coil Q factors. It also minimizes interaction with surrounding tissues and signal losses along the catheter coil. To investigate the technique, a prototype catheter coil was built using the proposed coaxial TLR technique and evaluated with standard RF testing and measurement methods and MR imaging experiments. Numerical simulation was carried out to assess the RF electromagnetic field behavior of the proposed TLR catheter coil and the conventional lumped-element catheter coil. 
Results: The proposed TLR catheter coil was successfully tuned to 64 MHz for proton imaging at 1.5 T. B1 fields were numerically calculated, showing improved magnetic field intensity of the TLR catheter coil over the conventional lumped-element catheter coil. MR images were acquired from a dedicated vascular phantom using the TLR catheter coil and also the system body coil. The TLR catheter coil is able to provide a significant signal-to-noise ratio (SNR) increase (a factor of 200 to 300) over its imaging volume relative to the body coil. 
Conclusions: Catheter imaging RF coil design using the proposed coaxial TLR technique is feasible and advantageous in endovascular interventional MR imaging applications.},
	issn = {2223-4306},	url = {https://qims.amegroups.org/article/view/12854}
}